手机号码:19121166298
地 址:上海市北京东路668号科技京城东楼27楼C1室
BALLUFF感应式距离传感器BAW0020
更新时间:2017-04-30 点击次数:611次
概览
组件
感应式距离传感器应用示例
插接器与连接导线 感应式距离传感器 适合的固定件
感应式距离传感器能够以 zui轻松简单的方式 识别金属材料的位置、尺寸和材质 。与 距离成比例的输出信号开辟了 多种多样的应用可能。
优势
与距离成比例的模拟信号
紧凑、坚固且可靠
应用
监测机械制造领域中接合、 冲压或夹紧装置的运动
探测轴体的失衡及延展情况
感应式距离传感器 - 贴合您的要求
Keyfeatures
Size | M18 |
---|---|
Connection | Pigtail, M08x1-S49, 0,2m, PUR |
Linearity range Sl | 1...5 mm |
Output voltage at Sl min. | 0 V |
Output voltage at Sl max. | 10 V |
General attributes
Mechanical installation condition | Flush (shielded) |
---|---|
Power indicator | No |
Basic standard | BWN PR 44, IEC 60947-5-2, IEC 60947-5-7 |
Short-circuit protected | Yes |
Enclosure Type per IEC 60529 | IP67 |
Protected against polarity reversal | Yes |
Protected against miswiring | Yes |
Additional text | Values referenced to axial approach of St 37 target. For other materials correction factors are applied. When used in Balluff clamping holders, Ua may be reduced by max. 10% |
Series | M18 |
Electrical attributes
Connection type | Pigtail |
---|---|
Rated operating voltage Ue DC | 24 |
Rated frequency, AC | DC |
Rated insulation voltage Ui | 75 DC |
Electrical version | DC, direct current |
Ripple max. (% of Ue) | 15 |
Switching output | PNP / Analog |
Switching function | Voltage falling on approach |
Principle of operation | Inductive |
Limit frequency -3dB | 500 Hz |
Output voltage at Se | 5 V |
Slope U | 2,5 V/mm |
Non-linearity max. | ±120 µm |
No-load current max. Io at Ue | 10 mA |
Operating voltage | 15...30 V DC |
Mechanical attributes
Tightening torque | 25 Nm / 35 Nm |
---|---|
Cable short designation | LiFY11Y-O |
Cable length | 0,2 m |
Connector type | M08x1-S49 |
Oberflächenschutz | Nickel-plated |
Shock rating | Shock, half-sinus, 30 gn, 11ms |
Vibration rating | 55 Hz, 1 mm ampl., 3x30 min |
Ambient temperature Ta min. | -10 °C |
Ambient temperature Ta max. | 70 °C |
Degree of contamination | 3 |
Sensing surface material | PBT |
Housing material | Brass |
Cable jacket material | PUR |
Cable diameter D max. | 3,1 |
Response time | 1 ms |
Measuring speed max. | 40 m/s |
Optical operating temperature min. | 10 °C |
Optical operating temperature max. | 50 °C |
Max. temp. drift from end value | ±5.0 % |
Temperature coefficient min. | 0.0 µm/K |
Temperature coefficient max. | -4.0 µm/K |
Temperature coefficient typ. | -1.0 µm/K |
Repeat accuracy per BWN | ±8.0 µm |
Adjustment indicator | Yes |
Repeat acc. R of end value max. | 3 |
Rated operating dist. Se | 3 mm |